The dry-seal Wiggins gasholder is a device for storing gas, designed by John Wiggins and first manufactured in 1940 after being developed in 1936, and it saw widespread use across the United States. Rather than the classic telescoping tank sealed by a ring of water, it uses a rigid piston fitted with a flexible rubber sealing membrane that rolls between the tank shell and the piston as the stored gas volume rises and falls, giving a frictionless, self-centering seal. A dry-seal Wiggins holder is built from a foundation and concrete base, a main tank made up of a bottom, shell and roof, and the piston assembly with its deck and fender, along with anti-corrosive treatment and safety fittings such as pressure relief valves and level-monitoring instruments. Units built to this design range from about 200 to 165,000 cubic meters in capacity and operate at pressures of roughly 15 to 150 millibars. This description is adapted from Wikipedia contributors under CC BY-SA 4.0; changes were made. https://creativecommons.org/licenses/by-sa/4.0/
Facts
Classification
MaturityTRL 9: Actual System Proven in Operational Environment 1 Invented Year Sources
1. Wikipedia: Dry-seal Wiggins gasholder
Wikipedia article lead
Wiggins gasholder is a device designed to hold gas. Designed by John Wiggins in 1936, it was first manufactured in 1940 and achieved widespread
In Group: Mechanical and Gas Storage Systems, Lead
A dry-seal Wiggins gasholder is a device designed to hold gas.
View the SourceReader Challenges (0)
No disputes yet. Spotted an error or a better source? Open the first one.
Sign in to dispute this or suggest a correction.